ServerCool Server & Data Rack Cooling
In 1956 the Long Range Weapons Establishment’s computer room in Australia, used Eaton-Williams cooling equipment.Over the last 50 years Eaton-Williams has developed sophisticated and reliable cooling solutions for major telecoms companies, BT, Orange, Cable & Wireless, Belgacom, in addition to close control cooling for control rooms, computer suites and data centres. ServerCool now offer a one stop solution, for the increasing headache of removing the heat from their server racks, together with the EW group’s range of CRAC units and ancillary cooling equipment, all supported by an international Service & Maintenance team.
CDU Unit
The CDU (Cooling Distribution Unit) has been designed to provide close controlled cooling water for up to 6 data rack ‘Rear Door Heat Exchangers’ (referred to as RDHx’s), with a total maximum cooling capacity of 120kW for the CDU120 model or up to 150kW for the CDU150 model.The process side water (referred to as the ‘Secondary Circuit’) is a sealed pressurised system with the heat extracted from the rear door heat exchangers being rejected to a raw chilled water circuit via a stainless steel plate heat exchanger.The chilled water can either be part of the Building Services Chilled Water system or supplied from a dedicated chiller. This chilled water supply (referred to as the ‘Primary Circuit’) is filtered to 300µ using a filtration unit fitted internally to the cabinet.
Server Cabinets & Rear Door Heat Exchangers
Server Cabinets and Rear Door Heat Exchangers (RDHx) are designed to provide an environment for high heat density servers and IT equipment and remove up to 50kW of heat at source rejecting it to water rather than the room.
CDU Module
The CDU Module has been designed to provide close controlled cooling water for one data rack rear door heat exchanger or two racks with a total maximum cooling capacity of 20kW.The process side water (referred to as the ‘Secondary Circuit’) is a sealed pressurised system with the heat extracted from the rear door heat exchanger being rejected to a raw chilled water circuit.The chilled water can either be part of the Building Services Chilled Water system or from a dedicated chiller. This chilled water supply (referred to as the ‘Primary Circuit’) should be filtered
Key features
- Total maximum cooling capacity of 120kW for the CDU120 model
- Total maximum cooling capacity of 150kW for the CDU150 model
- Chilled water supply is filtered to 300µ
- Remove up to 50kW of heat at source